Imprint
iontodevice.com
Iontophoresis vs. Hyperhidrosis
Log in
Search
Forum for Iontophoresis Hyperhidrosis and excessive sweating
Register
iontodevice.com Forum Index
->
Iontophoresis
Post a reply
Username
Subject
Message body
Emoticons
View more Emoticons
Font colour:
Default
Dark Red
Red
Orange
Brown
Yellow
Green
Olive
Cyan
Blue
Dark Blue
Indigo
Violet
White
Black
Font size:
Font size
Tiny
Small
Normal
Large
Huge
Close Tags
Options
HTML is
ON
BBCode
is
ON
Smilies are
ON
Disable HTML in this post
Disable BBCode in this post
Disable Smilies in this post
Anti-Bot-Question
Tell me the colour of the sky when no clouds are upon
Sorry, but this stupid question shall keep away the bots from this forum. Please type your answer in the following text field (one word):
All times are GMT + 1 Hour
Jump to:
Select a forum
Hyperhidrosis Forum
----------------
Sweating Hyperhidrosis Discussion
Therapy / Methods for solution / Products for Hyperhidrosis
----------------
Iontophoresis
Success board
Problems with the treatment - No / only little / partial success board
Your quests to iontophoresis-device.com
----------------
General obscurities
XXX Priority support XXX
----------------
Only for our customers...
Idromed 4 / 5 PC and DC section
Hidrex GS400, PS500 and PSP1000 section
XXX Priority Problem board XXX started 23.10.2009
----------------
Active Problems
Topic review
Author
Message
support
Posted: Tue Jun 23, 2015 9:23 am
Post subject:
you can leave them overnight. the next morning just rinse with water and dry with soft towel.
Another reason why the machine stops at 28 could be your bodys resistance, take a look here:
https://www.iontodevice.com/hyperhidrosis/device-doesnt-start-stays-at-0-ma-reaches-not-25-ma-max-t29.html
markm186
Posted: Tue Jun 23, 2015 12:13 am
Post subject: Re: Re. vinegar
newyork wrote:
I soaked the electrodes in vinegar. The Idromed is working again. Thanks!
how long do you soak it for? I'm having the same problem.. seems like the machine can't reach 32 volts anymore. It stops at 28.
support
Posted: Mon Aug 18, 2014 1:02 pm
Post subject:
Great!
You are welcome!
newyork
Posted: Mon Aug 18, 2014 12:34 pm
Post subject: Re. vinegar
I soaked the electrodes in vinegar. The Idromed is working again. Thanks!
support
Posted: Tue Aug 05, 2014 3:14 pm
Post subject:
NO, never! only the plugs of the cables (the 4 Ends) that go into the machine and electrodes (and if the plug of the electrode plate seems to be covered with Patina also this...
newyork
Posted: Tue Aug 05, 2014 7:07 am
Post subject: Vinegar cleaning
Thanks for your response.
Should I also soak the metal tip of the
power cord
in vinegar?
support
Posted: Mon Aug 04, 2014 1:42 pm
Post subject:
Lowering the water level to 1mm above the grids lead to stronger currents
It seems that this is leveling at the maximum that the device can deliver and you need the most current the machine can deliver.
Please soak in the plugs of the cables in vinegar, clean them with tap water after this (maybe they've got patina too) for an hour, then plug and unplug them 10 times, then clean them again and retry.
Maybe the minerals you took orally have and impact on your bodys resistance. Also through hard training calluses are enhanced, this leads to higher body resistance too.
You can also try to use warm water in the tubs
newyork
Posted: Sun Aug 03, 2014 11:22 am
Post subject: No longer able to feel electrical connection
I have been using the Idromed 5 PS to treat sweating on my hands and feet for about 3 years. My maintenance regime is the following: I use the device every other day, 15 minutes at 18 mA for hands, 15 minutes at 25 mA for feet. Normally I feel a strong tingling sensation during the treatment, and my hands/feet have a slight red tint for 15-30 minutes afterwards. When the device works, my hands and feet become completely dry.
A few months ago, I became unable to feel the "tingling" sensation during treatment, and, after a week, sweating returned. I contacted support at Bindner Markus Medizintechnik to ask for help. They advised me to use less water in the tubs, while adding 1 teaspoon of baking soda. This fixed the problem. Before I contacted support, I was using 2.5 L of water in each tub. When I began using
1.5
L of water in each tub (with 1 teaspoon of baking soda), I was again able to feel the tingling sensation. The sweating went away after a week of treatment.
About 10 days ago, I again became unable to feel the strong tingling sensation during treatment. Although the Idromed
does
indicate that it has reached the correct mA level (18 when treating hands, 25 when treating feet), I feel almost no electrical current, and my hands/feet do not acquire any red tint during the treatment. Sweating is now returning.
I am still using 1.5 L of warm tap water in each tub, with 1 teaspoon of baking soda.
I use the stainless steel electrodes. I have polished them as well as I can with metal cleaner. I do not think that patinated electrodes are the problem.
My water source is the same as before. I tried using slightly more or less baking soda (or none at all), but this does not fix the problem.
I do not use any cream on my hands/feet.
I believe that I am well hydrated. (The last few days I tried drinking a lot of water an hour before using the Idromed, but this had no effect.)
There are two things that recently changed for me, and which could theoretically be relevant. First, I
stopped
taking the following vitamin supplements: calcium, D3, iron, zinc, vitamin E, vitamin C. Second, I started exercising a bit harder than I did previously.
What should I try next?
Thank you very much.